Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Planetary buildings: Difference between revisions

From EVE University Wiki
Launchpad: The launchpad no longer has storage above that of a storage facility, and formatting the superscript cubed.
m Command Centers: Formatting the superscripts for the cubic meters
Line 11: Line 11:
[[File:CommandCenter2.jpg|left|frameless]][[File:CommandCenter.png|right|Command Center Window]]Command Center is the first building to be deployed and provides the CPU and Powergrid for the colony. Oddly enough, there is actually no need to connect the Command Center to any of your other buildings, unless you want to take advantage of the storage or launch abilities, both of which are outmatched by a Launch Pad.
[[File:CommandCenter2.jpg|left|frameless]][[File:CommandCenter.png|right|Command Center Window]]Command Center is the first building to be deployed and provides the CPU and Powergrid for the colony. Oddly enough, there is actually no need to connect the Command Center to any of your other buildings, unless you want to take advantage of the storage or launch abilities, both of which are outmatched by a Launch Pad.


You can use the rocket icon (or double click the structure) to prepare a launch, picking items to include, up to the total capacity of the command center (500m3). The cost of exporting commodities from the Command Center is 50% greater than via a Launchpad, and it cannot support the import of items.
You can use the rocket icon (or double click the structure) to prepare a launch, picking items to include, up to the total capacity of the command center (500m<sup>3</sup>). The cost of exporting commodities from the Command Center is 50% greater than via a Launchpad, and it cannot support the import of items.


You can review the CPU and Powergrid use of your colony from the Command Center window. You can see the same display under the build menu, but only if you have any construction pending. In that case you'll also be able to see two bars indicating how much additional CPU and Grid will be consumed by the pending changes, plus a numeric display of the same.  
You can review the CPU and Powergrid use of your colony from the Command Center window. You can see the same display under the build menu, but only if you have any construction pending. In that case you'll also be able to see two bars indicating how much additional CPU and Grid will be consumed by the pending changes, plus a numeric display of the same.  
Line 17: Line 17:
If the Command Center is decommissioned, all other buildings in the colony will be lost!
If the Command Center is decommissioned, all other buildings in the colony will be lost!


The command center is 1000 m3 to transport, and is upgraded in place on the planet.  When first deployed, it has the profile of a Basic Command Center.  Each level increments the power, CPU, and cost as listed below. You need a level of the [[Skills:Planet_Management#Command_Center_Upgrades|Command Center Upgrades]] skill to use each Command Center upgrade beyond Basic.
The command center is 1000 m<sup>3</sup> to transport, and is upgraded in place on the planet.  When first deployed, it has the profile of a Basic Command Center.  Each level increments the power, CPU, and cost as listed below. You need a level of the [[Skills:Planet_Management#Command_Center_Upgrades|Command Center Upgrades]] skill to use each Command Center upgrade beyond Basic.


{| class="wikitable"
{| class="wikitable"
Line 29: Line 29:
|-
|-
|align="center"| 0
|align="center"| 0
|align="right"| 500 m3
|align="right"| 500 m<sup>3</sup>
|align="right"| 1,675 tf
|align="right"| 1,675 tf
|align="right"| 6,000 MW
|align="right"| 6,000 MW
Line 35: Line 35:
|-
|-
|align="center"| 1
|align="center"| 1
|align="right"| 500 m3
|align="right"| 500 m<sup>3</sup>
|align="right"| 7,057 tf
|align="right"| 7,057 tf
|align="right"| 9,000 MW
|align="right"| 9,000 MW
Line 41: Line 41:
|-
|-
|align="center"| 2
|align="center"| 2
|align="right"| 500 m3
|align="right"| 500 m<sup>3</sup>
|align="right"| 12,136 tf
|align="right"| 12,136 tf
|align="right"| 12,000 MW
|align="right"| 12,000 MW
Line 47: Line 47:
|-
|-
|align="center"| 3
|align="center"| 3
|align="right"| 500 m3
|align="right"| 500 m<sup>3</sup>
|align="right"| 17,215 tf
|align="right"| 17,215 tf
|align="right"| 15,000 MW
|align="right"| 15,000 MW
Line 53: Line 53:
|-
|-
|align="center"| 4
|align="center"| 4
|align="right"| 500 m3
|align="right"| 500 m<sup>3</sup>
|align="right"| 21,315 tf
|align="right"| 21,315 tf
|align="right"| 17,000 MW
|align="right"| 17,000 MW
Line 59: Line 59:
|-
|-
|align="center"| 5
|align="center"| 5
|align="right"| 500 m3
|align="right"| 500 m<sup>3</sup>
|align="right"| 25,415 tf
|align="right"| 25,415 tf
|align="right"| 19,000 MW
|align="right"| 19,000 MW