Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Target Spectrum Breaker: Difference between revisions

From EVE University Wiki
Dozyʹ m (talk | contribs)
Evidence/Data: analysis
Dozyʹ m (talk | contribs)
Evidence/Data: formating, percent
Line 56: Line 56:


L4 Angel Extravaganza, Bonus Room, Single Spawn Not Triggered. Target breaker skill 4.  Full Room Aggro. Rattlesnake: 30 Gravimetric Sensor Strength. Nothing Targeted. Target Spectrum Breaker activated once (set autorepeat off), screenshot to count results. Sensor strength numbers from http://npc.elfarto.com
L4 Angel Extravaganza, Bonus Room, Single Spawn Not Triggered. Target breaker skill 4.  Full Room Aggro. Rattlesnake: 30 Gravimetric Sensor Strength. Nothing Targeted. Target Spectrum Breaker activated once (set autorepeat off), screenshot to count results. Sensor strength numbers from http://npc.elfarto.com


If you watch carefully, the jams aren't simultaneous. Difficulties include printscreen when non-jammed rats are blinking faded.  
If you watch carefully, the jams aren't simultaneous. Difficulties include printscreen when non-jammed rats are blinking faded.  


beginning of cycle:
beginning of cycle:
1x Gist Malakim 24 (L)adar sensor strength
1x Gist Malakim 24 (L)adar sensor strength
1x Tower Sentry Angel II 100 for all types
1x Tower Sentry Angel II 100 for all types
TOTAL: 124L, 100(M)agnetometric, 100(R)adar, 100(G)ravimetric
TOTAL: 124L, 100(M)agnetometric, 100(R)adar, 100(G)ravimetric


1/4 through cycle:
1/4 through cycle:
1x Angel Webifier [NEW!] 10L
1x Angel Webifier [NEW!] 10L
1x Gist Malakim
1x Gist Malakim
1x Tower Sentry Angel III [NEW!] 100G 100R 100M 100L
1x Tower Sentry Angel III [NEW!] 100G 100R 100M 100L
1x Gistatis Legatus [NEW!] 19L
1x Gistatis Legatus [NEW!] 19L
2x Tower Sentry Angel II [1 NEW!] 100G 100R 100M 100L
2x Tower Sentry Angel II [1 NEW!] 100G 100R 100M 100L
TOTAL 229L 200(M)agnetometric, 200(R)adar, 200(G)ravimetric
TOTAL 229L 200(M)agnetometric, 200(R)adar, 200(G)ravimetric


1/2 through cycle:  
1/2 through cycle:  
1x Angel Webifier
1x Angel Webifier
1x Gist Malakim
1x Gist Malakim
2x Arch Gistum Breaker [NEW!] 34x2=68L
2x Arch Gistum Breaker [NEW!] 34x2=68L
1x Gistatis Legatus
1x Gistatis Legatus
1x Gistatis Tribunus (yellowbox) [NEW!] 19L
1x Gistatis Tribunus (yellowbox) [NEW!] 19L
1x Tower Sentry Angel III [NEW!] 100G 100R 100M 100L
1x Tower Sentry Angel III [NEW!] 100G 100R 100M 100L
TOTAL 187L 100G 100R 100M
TOTAL 187L 100G 100R 100M


3/4 through cycle:
3/4 through cycle:
1x Gist Malakim
1x Gist Malakim
2x Arch Gistum Breaker
2x Arch Gistum Breaker
1x Gistatis Legatus
1x Gistatis Legatus
1x Gistatis Tribunus (yellowbox)
1x Gistatis Tribunus (yellowbox)
1x Gist Nephilim [NEW!] 31L
1x Gist Nephilim [NEW!] 31L
TOTAL 31L
TOTAL 31L


That's 11 of 28 different rats in one 9.60second cycle. Total sensor strength jammed: 571L 400MGR.
 
Rats jammed: 11 of 28 (39%)in one 9.60second cycle. Sensor strength doesn't seem to play a role since 100L towers jammed. Total sensor strength jammed: 571L 400MGR out of 1382L 700MGR (41% 57%).


==Proposed Testing==
==Proposed Testing==