More actions
No edit summary |
|||
| Line 239: | Line 239: | ||
|} | |} | ||
While this illustrates the power of the module, fitting six of them to a ship would be unrealistic. Three modules is a common fit, with the other slots used for other purposes. Thus, with no other skills or fittings, three Shield Power Relays would increase the ''<span style="color:#ffeeee">Peak</span>'' Recharge Rate to 17. | While this illustrates the power of the module, fitting six of them to a ship would be unrealistic. Three modules is a common fit, with the other slots used for other purposes. Thus, with no other skills or fittings, three Shield Power Relays would increase the ''<span style="color:#ffeeee">Peak</span>'' Recharge Rate to 17.3 hitpoints per second. | ||
For comparison, a medium Phased Plasma projectile does about 18 hp base shield damage plus 24 hp type damage; a medium Lead Hybrid charge does about 10 hp base shield damage plus 16 hp type damage. | For comparison, a medium Phased Plasma projectile does about 18 hp base shield damage plus 24 hp type damage; a medium Lead Hybrid charge does about 10 hp base shield damage plus 16 hp type damage. | ||
| Line 257: | Line 257: | ||
Peak Recharge Rate = 2.5 x 4.9 = 12.3 hp/s | Peak Recharge Rate = 2.5 x 4.9 = 12.3 hp/s | ||
The original base Peak Recharge Rate was 7. | The original base Peak Recharge Rate was 7.6 hp/s. So adding a large shield extender increases the recharge rate by 4.7 hp/s; an increase of 62%. | ||
====Core Defense Purger Rigs==== | ====Core Defense Purger Rigs==== | ||
| Line 271: | Line 271: | ||
The bare ship had: | The bare ship had: | ||
*Base shield capacity: | *Base shield capacity: 4250 hp | ||
*Base recharge time: | *Base recharge time: 1400 sec | ||
*Average regeneration rate = | *Average regeneration rate = 4250 / 1400 = 3.0 hp/s | ||
*Base peak regen rate = 2.5 x 3.1 = | *Base peak regen rate = 2.5 x 3.1 = 7.6 hp/s | ||
After one Large Shield Extender II (see above): | After one Large Shield Extender II (see above): | ||
*Shield capacity: | *Shield capacity: 6850 hp | ||
Three Power Shield Relay II (see above): | Three Power Shield Relay II (see above): | ||
*Modules @ -24% | *Modules @ -24% | ||
*Shield capacity: | *Shield capacity: 6850 hp | ||
*Peak Recharge Rate = Shield Capacity/Recharge Time x 2.5 | *Peak Recharge Rate = Shield Capacity/Recharge Time x 2.5 | ||
| Line 293: | Line 293: | ||
|Recharge Time || 1064 || 808.6 || 614.3 | |Recharge Time || 1064 || 808.6 || 614.3 | ||
|- | |- | ||
|Peak Regeneration Rate || 16. | |Peak Regeneration Rate || 16.1 || 21.2 || 27.9 | ||
|} | |} | ||
</div> | </div> | ||