Difference between revisions of "Planetary buildings"

From EVE University Wiki
Jump to: navigation, search
(→‎Overview: Cleanup for conciseness; standardized capitalization and passive/active voice; expanded information)
(→‎Command Centers: grammar fixes, standardized capitalization/naming conventions, edited for conciseness and clarity)
Line 7: Line 7:
  
 
== Command Centers ==
 
== Command Centers ==
[[File:CommandCenter2.jpg|left|frameless]][[File:CommandCenter.png|right|Command Center Window]]Command Center is the first building to be deployed and provides the CPU and Powergrid for the colony. Oddly enough, there is actually no need to connect the Command Center to any of your other buildings, unless you want to take advantage of the storage or launch abilities, both of which are outmatched by a Launch Pad.
+
[[File:CommandCenter2.jpg|left|frameless]][[File:CommandCenter.png|right|Command Center Window]] The Command Center is the first building to be deployed and provides the CPU and Powergrid for the colony. Oddly enough, there is actually no need to connect the Command Center to any of your other buildings, unless you want to take advantage of the storage or launch abilities, but a Launchpad has superior capabilities for both, albeit at the cost of more CPU and Powergrid.
  
To deploy the Command Center you just need to be in space in the system with it in your hold and then view the planet in planet mode. On the build "tab" there will be a Command Center item listed which you will click, showing the command center type for the planet. Assuming you have that type of command center in your hold you can then click it and click where you want to place it. Click submit and you are the proud owner of a new colony.
+
To deploy the Command Center you need to be in space with it in your cargo hold and view the planet in planet mode. Under the build menu there will be a Command Center submenu which when clicked shows the Command Center type for the planet. Assuming you have that type of Command Center in your cargo hold, you can select and place it. Click "Submit" and you are the proud owner of a new colony.
  
You can use the rocket icon (or double click the structure) to prepare a launch, picking items to include, up to the total capacity of the command center (500m<sup>3</sup>). The cost of exporting commodities from the Command Center is 50% greater than via a Launchpad, and it cannot support the import of items.
+
You can use the rocket icon (or double click the structure) to launch commodites stored at the Command Center, up to its total capacity of 500m<sup>3</sup>. However, exporting costs 50% more from a Command Center than from a Launchpad, and unlike a Launchpad a Command Center cannot import commodities.
  
You can review the CPU and Powergrid use of your colony from the Command Center window. You can see the same display under the build menu, but only if you have any construction pending. In that case you'll also be able to see two bars indicating how much additional CPU and Grid will be consumed by the pending changes, plus a numeric display of the same.  
+
You can review the CPU and Powergrid use of your colony from the Command Center window. You can see the same display under the build menu, but only if you have any construction pending. In that case you'll also be able to see two bars indicating how much additional CPU and Powergrid will be consumed by the pending changes (the area past the vertical white lines), plus a numeric display of the same.  
  
 
If the Command Center is decommissioned, all other buildings in the colony will be lost!
 
If the Command Center is decommissioned, all other buildings in the colony will be lost!
  
The command center is 1000 m<sup>3</sup> to transport, and is upgraded in place on the planet.  When first deployed, it has the profile of a Basic Command Center.  Each level increments the power, CPU, and cost as listed below. You need a level of the [[Skills:Planet_Management#Command_Center_Upgrades|Command Center Upgrades]] skill to use each Command Center upgrade beyond Basic.
+
The Command Center has a volume of 1000 m<sup>3</sup>, and is upgraded in place on the planet.  When first deployed, it has the profile of a Basic Command Center.  Each level increments the power, CPU, and cost as listed below. You need a level of the [[Skills:Planet_Management#Command_Center_Upgrades|Command Center Upgrades]] skill to use each Command Center upgrade beyond Basic.
  
 
{| class="wikitable"
 
{| class="wikitable"

Revision as of 16:36, 24 June 2014

This article should be cleaned up or improved. The reason is: unspecified

Overview

All planetary structures are placed via Planet Mode, after you've placed a Command Center for the appropriate planet type and clicked "Submit." To deploy a Command Center you must have one in your cargo hold and be undocked in the desired system. You can build and manage any of the other structures while docked or in space from anywhere in the universe via the "Planets" tab of the Science and Industry window of your NeoCom.

Command Centers

CommandCenter2.jpg
Command Center Window

The Command Center is the first building to be deployed and provides the CPU and Powergrid for the colony. Oddly enough, there is actually no need to connect the Command Center to any of your other buildings, unless you want to take advantage of the storage or launch abilities, but a Launchpad has superior capabilities for both, albeit at the cost of more CPU and Powergrid.

To deploy the Command Center you need to be in space with it in your cargo hold and view the planet in planet mode. Under the build menu there will be a Command Center submenu which when clicked shows the Command Center type for the planet. Assuming you have that type of Command Center in your cargo hold, you can select and place it. Click "Submit" and you are the proud owner of a new colony.

You can use the rocket icon (or double click the structure) to launch commodites stored at the Command Center, up to its total capacity of 500m3. However, exporting costs 50% more from a Command Center than from a Launchpad, and unlike a Launchpad a Command Center cannot import commodities.

You can review the CPU and Powergrid use of your colony from the Command Center window. You can see the same display under the build menu, but only if you have any construction pending. In that case you'll also be able to see two bars indicating how much additional CPU and Powergrid will be consumed by the pending changes (the area past the vertical white lines), plus a numeric display of the same.

If the Command Center is decommissioned, all other buildings in the colony will be lost!

The Command Center has a volume of 1000 m3, and is upgraded in place on the planet. When first deployed, it has the profile of a Basic Command Center. Each level increments the power, CPU, and cost as listed below. You need a level of the Command Center Upgrades skill to use each Command Center upgrade beyond Basic.

Command Center Properties
Level Capacity CPU Provided Power Provided Upgrade Cost
0 500 m3 1,675 tf 6,000 MW N/A
1 500 m3 7,057 tf 9,000 MW 580,000 ISK
2 500 m3 12,136 tf 12,000 MW 930,000 ISK
3 500 m3 17,215 tf 15,000 MW 1,200,000 ISK
4 500 m3 21,315 tf 17,000 MW 1,500,000 ISK
5 500 m3 25,415 tf 19,000 MW 2,100,000 ISK


Planetary Structures

Structure Properties
Name CPU Required Power Required Cost
Extractor Control Unit 400 tf 2600 MW 45,000.00 ISK
Extractor Head 110 tf 550 MW 0.00 ISK
Basic Industry Facility 200 tf 800 MW 75,000.00 ISK
Advanced Industry Facility 500 tf 700 MW 250,000.00 ISK
High-Tech Industry Facility 1100 tf 400 MW 525,000.00 ISK
Storage Facility 500 tf 700 MW 250,000.00 ISK
Space Port 3600 tf 700 MW 900,000.00 ISK

Extractor Control Units

Extractors2.jpg
Extractor Window

The Extractor Control Unit (ECU) is the main facility that handles the extraction of a specific planetary resource. You must set up a route for the resources to go to either storage or a basic processor.

After selecting the ECU on the build tab, a large transparent circle will be visible around the icon while hovering over the planet screen. This is the area in which extractor heads can be placed and operated after placement of the ECU.

You need to confirm changes before you can move on the the next step: programming the ECU and the extractor heads. After confirming, click the first button on your ECU page called "survey". You will be presented by a screen containing 10 small circles to the left labeled "extractor head units", an "extraction area size" slider below that and 5 potential planetary products on the top right. Begin by selecting the desired product. The planet will be colored according to your scan settings for the selected product. Next, set the extraction area size slider to the time you want to extract materials using the selected program. Setting a very long program (max 14 days) will make the extractor heads extract on a very large area, but only extract once every few hours. Selecting a short program will allow you to mine with pinpoint accuracy and get resources several times per hour. Finally, click on the first circle to attach an extractor head to your ECU. Move the extractor head to the desired location (see extractor heads below). After adding the desired amount of extractor heads (maximum of 10 per ECU), you can install the program and the display will change to the the ECU's product tab.

Simply click the output of your extractor in the list, then click "Create Route" and select your target destination. You have to have a link in place, but can build it in the same submit cycle - no need to commit any actions other than building the extractor itself before doing everything else. If you forget this step or want to continue with another action first (like creating a link) you can always return to the products tab by hitting the second button on your ECU display labeled "products"

Extractor Heads

Extractor Heads

Extraction of resources is done by extractor heads that are installable via the Extractor Control Units (ECU). The heads can be placed within the ECUs area and can be moved via drag and drop. The links between the heads and the ECUs do not add power or CPU but every added head (up to a maximum of 10) needs an amount of power (550) and CPU (110).

The main idea for extractor heads is to move them around to resource hot-spots for a greater extraction amount. By placing the ECU in a way that the ECUs area is surrounding several hot spots the extractor heads can be placed on different hot-spots every time a program is installed. Using this method the depletion of the resource is balanced between the hot-spots.

The area of effect of one extractor head is dependent on the length of the installed program. Longer programs mean a wider area of effect for the extractor heads. When the areas are overlapping a penalty of extraction amount is displayed as red numbers in the ECU window.


Processors

Processors, also known as factories, are used to convert one type of planetary resource or product into a different product. See Planetary Commodities for details on the various combinations you can use. A processor waiting for materials will have its "Progress ring" slowly pulsing.

For the first two tiers Processors are especially useful by decreasing the volume of the involved materials. Turning raw resources (R0) into P1 goods will reduce the total volume to about 25% of the original, and to another 25% of that if worked to P2 goods. After that point the volume reduction becomes less substantial and it becomes impossible to find a single planet to run the whole process perfectly from start to finish without the export/import of material.

Basic Industry Facility

Bp2.jpg
Basic Processor Window

A Basic Processor turns planetary resources into the first level of products. You have to select which "Schematic" to produce via the first icon (simply double clicking the structure works too) where a drop-down will reveal all the P1 products. For instance, the first item "Bacteria" will set the Processor to take Micro Organisms as input and create Bacteria as output.

You must route a planetary resource to the Processor either directly from an Extractor or from storage. After selecting your schematic you'll be forwarded to the Products menu, where just like an Extractor you'll have to select the output, click "Create Route", and pick a target destination for the product.

Be careful about routing your input directly from Extractors, as the Processor only has "storage" capacity for exactly one cycle, with anything else routed to the Processor being lost!


Advanced Industry Facility

Ap2.jpg
Advanced Processor Window

Advanced Processors are just like Basic Processors, with the exception that they produce P2 and P3 goods, with each either two or even three input products.

Again you have to select a schematic and then route input material to the Processor. P2 schematics take exactly two P1 products as input, while P3 schematics take either two or even three P2 products. The icon of the structure will change to show two or three "bars" wrapping the icon based on whatever it is producing, so you cannot tell Advanced and High Tech Processors apart from their icon, although it would be easy to get that impression.

Advanced processors, like their Basic siblings, will store up to exactly one batch of input materials, so be careful about waste!

P3 advanced factories will need two p2 advanced factories feeding it per required input product to keep it running at full efficiency.


High Tech Production Plant

Hp2.jpg
High Tech Processor Window

At this point you probably think you've spotted the pattern with Processors and you're just about right! The only real surprise out of this final tier of Processor, which makes tier 4 Products (P4) is that they can only be built on Barren or Temperate planets.

They take three input goods, either three P3 or two P3 and one P1. Each output P4 item is a full 100 m3 in volume.

You need two P3 factories per input product to keep p4 running at full production


Storage Facilities

Storage2.jpg
Storage Facility Window

A Storage Facility is a relatively cheap way to make a buffer to hold resources or product prior to being converted or shipped to orbit. However, unless you really have substantial logistical needs on your planet, you might be better off relying on your Command Center or a Launchpad. Storage facilities originally held 5000 m3 (as in the picture) but that was increased to 12,000 m3 in the Crucible 1.1 patch making Storage Facilities more useful.

Instead of routing straight from your Extractors to Processors (at a potential risk of waste) you can first route to Storage, then route from Storage to Processor. One issue is that you cannot use routes to transfer between different Storage - so if your goal is to export a commodity, you'll want to route it straight to the Command Center or a Launchpad.

If you do end up needing to move something between Storage, you can use the "Expedited Transfer" option under the Storage icon on either Storage Facilities, Launchpads, or Command Centers. Simply move the goods you want to be part of the transfer to the center panel. Note that while this option costs no ISK, it does have a cooldown!

Launchpad

LP2.jpg
Launchpad Window

An alternative to using your Command Center as a launching point. Launchpads have more storage than Command Centers in which they can hold up to 10,000m3 of resources and products and are less expensive for exporting goods to orbit.

When the first Launchpad is created on a particular planet a corresponding Customs Office is created in orbit. This orbital structure will connect to all Launchpads on the planet, regardless of location and owner. The Customs Office essentially provides a private hangar for all users and is the only way to move material down to the planet surface (import). Since there is only ever this single orbital point, it offers tremendous ambush potential.

Select "Access Customs Office" from anywhere you can select the Customs Office, or simply click the Rocket icon on your Launchpad controls directly (or just double-click the structure). This will work even from great range, but you must be present in orbit to actually transfer items to and from your ship.

See Colony Management for more details on using the Customs Office.


Planetary Links

Launchpad Window

Links are used to connect planetary buildings together so that you can route goods between them. You can CTRL-click a structure to automatically start placing a link starting from that location, then click a target. You can also build links from the main menu like all other structures, or even do so via the link menu on an existing structure. Like most other actions you have to hit "Submit" before the links are created, but you can start planning out routes before the links are created.

You do not need direct links between all your buildings - you can connect buildings to each other and route materials through them, up to a maximum of 6 hops. Do note that links have a capacity, and the more routes that pass through the same link, the more that capacity will be impacted. If your link design include any "bottleneck" links you may have to upgrade that link to a higher capacity.

You can see current usage of link capacity as a percentage above the link while you are either hovering the mouse above the link or simply hover over a building to see all links involved in routes to / from that building.

In addition to the base rate to build a link (10 PG+15 CPU), it also costs 0.20 cpu and 0.15 power per kilometer. This means links can be more expensive on larger planets. A handy table is available to estimate your cost.

See Planetary Industry for more details on how to plan and use your Links efficiently.

Link Cost By Distance

PI LinkPerKm.jpg
Link Cost by Distance
Distance CPU Required Power Required
2.5 km 16 tf 11 MW
10 km 18 tf 12 MW
20 km 20 tf 14 MW
50 km 26 tf 18 MW
100 km 36 tf 26 MW
200 km 56 tf 41 MW
500 km 116 tf 86 MW
1000 km 215 tf 160 MW
2000 km 416 tf 311 MW
5000 km 1016 tf 761 MW
40000 km 8016 tf 6001 MW


Link Upgrade Costs

Data on relative costs of upgrading the link capacity (uses a link that is 500km as a base):

Level Capacity CPU Required Power Required
0 250 m3 116 tf 86 MW
1 500 m3 280 tf 183 MW
2 1000 m3 481 tf 291 MW
3 2000 m3 713 tf 407 MW
4 4000 m3 968 tf 528 MW
5 8000 m3 1245 tf 655 MW
6 16000 m3 1542 tf 786 MW
7 32000 m3 1855 tf 921 MW
8 64000 m3 2185 tf 1059 MW
9 128000 m3 2530 tf 1200 MW
10 256000 m3 2889 tf 1344 MW

The increase in capacity adds 100% over the previous level.

Notice that as you upgrade the link to higher levels, the CPU usage scales faster than powergrid usage. (2010-04-29 upgrade costs no ISK, unclear whether it will stay that way.) The CPU and PG penalty declines as the level goes higher. Looking at the CPU, level 1 adds a 162% increase in CPU usage over the previous level, but going from level 9 to 10 adds only 14% increase (though level 10 is 28.5 times greater than level 0 link cost). Level 1 power grid adds a 128% increase, from level 9 to 10 adds 12% increase, and level 10 is 17.5 times the level 0 link cost.

However, in a high sec planet, you will be hard-pressed to use up the level 0 capacity of 250 m3 on most links, though depending on your layout, you might have to upgrade the occasional link by 1-2 levels.